============================================================================= Intel(R) Server Platform S1200SP FRU/SDR Update Release Notes ============================================================================= INTEL Enterprise Platform & Services Marketing Intel Corporation 2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA ============================================================================= DATE: August 30, 2017 TO: Intel(R) Server Platform S1200SP customers SUBJECT: IBMC(R) FRU/SDR update package S1200SP_FRUSDR_026 release notes ============================================================================= LEGAL INFORMATION ============================================================================= Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel Corporation may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a registered trademark of Intel Corporation. *Other names and brands are the property of their respective owners. Copyright (c) 2018 Intel Corporation. ============================================================================= ABOUT THIS RELEASE PACKAGE ============================================================================= SDR file version: 0.26 Baseboard FRU file version: 0.01 Master configuration file version: 0.17 FRUSDR loader version: 14.0 Build 11 FRU/SDR release notes: 0.26 SDR data based on system/thermal team SDR spreadsheet rev 1.00 ============================================================================= SYSTEM HARDWARE & SOFTWARE REQUIREMENTS/REVISIONS ============================================================================= - S1200SP baseboard PBA G29130-XXX or higher. - E3-1200v5 S processor A0 stepping or higher. - BMC FW 00.06 or later - BIOS R0023 or later - Front Panel, Hot-swap backplane, and Baseboard FRU data must be available for chassis auto-detection to succeed. ============================================================================= IMPORTANT INSTALLATION NOTES ============================================================================= NOTE: If you updated BIOS and did not clear CMOS Ram, you should do that before installing this package. NOTE: You need to have ME FW 3.05 or later installed for the SSB Temp sensor to work properly. ============================================================================= INSTALLATION PROCEDURE ============================================================================= 1. Ensure BMC FW release 00.04 or later and BIOS R0001 or later are pre-installed before attempting this FRU/SDR update. 2. Copy all of the files and directories in the S1200SP_FRUSDR_019.zip archive to a USB key, hard disk drive or floppy drive. 3. If the board FRU information has not been previously programmed, then default FRU information must be programmed before the update is started. This is done with the following command: frusdr.efi /fru s1200sp.fru 4. Execute the following script to bring up the main FRU/SDR load menu: updS1200SP.nsh 5. Select Option 1 or 3 to do the SDR update. 6. The package should do an auto-config. If it does not, it will print an error message indicating why auto-detection failed and then present the standard chassis selection menu. ============================================================================= KNOWN ISSUES/WORKAROUNDS ============================================================================= ============================================================================= ISSUES FIXED ============================================================================= S1200SP_026: 2103618193 Display version 0.24 in flash interface when flash Frusdr version 0.25. S1200SP_025: S1200SP_024: 1504411216 "Agg Therm Mgn 1" sensor is reporting an upper critical level as SDR define not the same as other platform. S1200SP_023: EPSD100256650 OFU_v14.0.14 can not get frusdr fw version info from FTP server on S1200SP-Refresh platform. S1200SP_022: EPSD100255996 SDR update info and product update area info output at the same line when update FRUSDR with nac mode on S1200SP platform. EPSD100256122 The SDR version by run command ¡§flashupdt ¡Vi ¡Vu frusdrupdate.cfg¡¨ does not match with the system frusdr 0.21. S1200SP_021: S1200SP_020: EPSD100034015 When use KBL CPU to Updated FRUSDR 0.19, system detect CPU model as SKL. S1200SP_019: EPSD100030561 1U 450W PSU LED behavior did not meet BKM during different temp threshold. S1200SP_018: S1200SP_017: EPSD100250253 FRUSDR v0.15 Master.cfg loads chassis intrusion SDR for 1U rack system S1200SP_016: EPSD100029982 In SKU7 (P4000XXSHDR+HSBP SAS (12G*8)), HDD4~7 can be detected by OS, but it doesn't show "Drive Presence" in sensor HDD status. S1200SP_015: EPSD100029996 It shows version 0.14 in the master.cfg file of FruSdr 0.15 package S1200SP_014: EPSD100029588 The PS1 Curr Out % status shows "Unknow" in sensor readings of EWS(1U,350W). S1200SP_013: EPSD100029394 After remove/restore system FAN 1/2/3, it cannot occur correct event in BMC. S1200SP_012: EPSD100248819 There's no Exit Air Temp sensor after updated FRUSDR on P2 SUT without HSBP. S1200SP_011: EPSD100248659 The PSU's Fan boost to high speed after update to FRUSDR 0.10. S1200SP_010: EPSD100028987 The "0x20 BB P1 VR Temp" and "0x25 BB Mem VR Temp" sensors show "NA" threshold in BMC WebUI EPSD100247316 There should be no "Exit Air Temp" sensor with Fixed PSU. EPSD100248624 No sensors defined for domain 6 in the global Fan Sensor Domain Map record. EPSD100248633 When run FSC scripts on SUT P2, always message " FAIL: Main Domain record has no Sub-Records. Skipping this record." EPSD100248637 [SVP_FSC]FAIL: Reading Mask & Settable / Readable Threshold field expected to be 0x0000, actual value is 0x1010. S1200SP_009: EPSD100248497 The SDR has no system airflow information for domain 0/2. S1200SP_008: EPSD100028701 After heating up the HSBP temperature sensor over 111 degree, the status of "HSBP Temp" will show "Not available" and it will log "HSBP Health offline" event in SEL.(screenshot) S1200SP_007: EPSD100248275 The Auto Fan Profile record has an illegal value. The Minimum performance profile is out of range. EPSD100028700 After cooling down the HSBP temperature sensor below 0 degree, the status of "HSBP Temp" will show "Upper Critical" and reading shows 237 degree.(screenshot) EPSD100248301 SDR Record #0xBA has a conflicting Stepwise Sub-Record defining the lower curve record for Domain:6, Profile:0x0~0x7 S1200SP_006: S1200SP_005: EPSD100028286 In FCN chassis, there should be only 1 processor fan and 1 rear system fan, but it detect 1 processor fan and 2 system fans. EPSD100027871 In HCN chassis, there should be only 1 processor fan and 1 system fan, but it detect 1 processor fan and 2 system fans. EPSD100028426 After disconnect the HSBP I2C, BMC will log Consistency Check/Parity S1200SP_004: S1200SP_003: EPSD100247114 Can't show all HDD status in sensor reading page on EWS EPSD100247316 There should be no "Exit Air Temp" sensor with Fixed PSU. EPSD100027848 The BB P1 VT Temp sensor (actually should be BB P1 VR Temp) threshold value shows "NA" EPSD100247238 Rear HDD 0 Stat sensor always in unknown state. EPSD100027750 According to BMC SPEC v0.8, the "BB P1 VT Temp" should be "BB P1 VR Temp". S1200SP_002: EPSD100246913 System fan 1 status is incorrect while removed EPSD100246912 Processor Fan sensor is mismatched with System Fan 1 in sensor reading page on EWS EPSD100246905 there is no sensor for power supply in Sensor reading page on EWS EPSD100246895 String "HSBP 0 Health" for HSBP Health sensor is incorrect. EPSD100246894 There is no "P1 Thermal margin" sensor in sensor reading page on EWS EPSD100246867 MTT cpu2 sensor is not supposed to appear in EWS sensor page. EPSD100246858 BB Mem VR temp sensor is always in Critical state. EPSD100246857 BB P1 VT Temp sensor is always in Critical state EPSD100027560 No beep code 1-5-2-1 and no CPU missing evet assert when power on the SUT without CPU. S1200SP_001: - First release ============================================================================= FEATURES ADDED ============================================================================= S1200SP_026: S1200SP_025: - Update FRUSDR utility to v14.0 Build 11. S1200SP_024: - Modify 'Agg Thrm Mgn 1' Sensor's reading mask from 1010 to 0000. - Modify 'Front Panel Temp' Sensor's reading mask from 3B3B to 1B1B. S1200SP_023: - Modify ProductName field of 450W PSU to support new type "DPS-500WB-2 C". - Remove "S2600WTT.fru" definition in master.cfg S1200SP_022: - Add "DISPLAY ¡§ ¡§" in end of product info update in master.cfg S1200SP_021: - Update FRUSDR utility to v14.0 Build 8. S1200SP_020: - Remove "SKL-S" string of PROCESSOR message in master.cfg. S1200SP_019: - Follow Silver_FSC_Config_Sheet_Rev0.94 S1200SP_018: - Follow Silver_FSC_Config_Sheet_Rev0.93,0.92 S1200SP_017: - NO_INTRUSION no need to load sdr record. S1200SP_016: - Follow Silver_FSC_Config_Sheet_Rev0.91 - HSBP 2 sensor number is : F8h,F9h,FAh,FBh,not F4h,F5h,F6h,F7h. - Modify master.cfg for P/N changed of Front Panel board and 4-bay 3.5¡¨ HDD HSBP for 1U rack. S1200SP_015: - Follow Silver_FSC_Config_Sheet_Rev0.85 S1200SP_014: - Follow Silver_FSC_Config_Sheet_Rev0.7 - 350W PSU does NOT support ¡§Current Out¡¨ reading, SDR remove it. S1200SP_013: - Modify fan sensor # not match for 1U rack system. - Modify HSBP board 4-bay 3.5¡¨ HDD for 1U rack.It's P/N of FRU data is 'FR1304S3' not 'FR1304S3HSBP'. S1200SP_012: - Follow Silver_FSC_Config_Sheet_Rev0.53 - Remove sensor# '2Eh' from FSC-P1. S1200SP_011: - Modify Global stepwise header record of PS S1200SP_010: - Follow Silver_FSC_Config_Sheet_Rev0.52 - Modify 'BB P1 VR Temp' and 'BB Mem VR Temp' two Sensor's UNC (from NA to 5) and UC (from NA to 10). - Modify 'System Airflow' sensor# 11h,Reading Mask & Settable / Readable Threshold Masks from 1010 to 0000. - Modify FSC-P1 UPS, fan failure sub-record. - Modify FSC-P2 UPS, discard all profile, domain 2 SDR record. - Modify 'Exit Air Temp' sensor# 2Eh, SDR record not support for FSC-P1 UPS. S1200SP_009: - Modify 'P1 DTS Therm Mgn' Sensor Maximum Reading from 00 to 7F. - Modify 'System Airflow' Sensor Normal/Maximum Reading. - Modify Global Clamp Header Record ID :0x74 & 0x94, clamp temperature from 0 to -10(F6). - Modify System Airflow Formula Domain mask : UPS 2Fan (02 to 03),UPS 3Fan (02 to 07). - Modify HDD power weight. S1200SP_008: - Follow Silver_FSC_Config_Sheet_Rev0.51 - Modify HSBP 1/2/3 TEMP SDR,UNC,UC value. - Modify system fan 1/2/3/4 and cpu fan SDR of FCT. - Modify Global Clamp header Record (80h/25h/22h/5ch/5dh) Clamp Temp. - Modify Global Stepwise Curve Record(ID : 45). - Add 1U rack SKU support. S1200SP_007: - Modify HSBP 1/2/3 TEMP SDR,Sensor Units 1,Sensor Maximum/Minimum Reading - Modify Autoprofile record,Minimum performance profile value - Modify Global Stepwise Curve ID (18h = 24),Domain max and count from 03 to 83 S1200SP_006: - Follow Silver_FSC_Config_Sheet_Rev0.5 S1200SP_005: - Modify 'System Fan 1' SDR_TAG from P4000 to P4000_4X_3FAN - Modify HSBP 1/2/3 health SDR, Sensor Type,and Event/Reading Type S1200SP_004: - Follow Silver_FSC_Config_Sheet_Rev0.42 - Modify Global stepwise curve ID 100 Domain Maximun - Rename sensor name IERR to CATERR S1200SP_003: - Correct sensor name from "BB P1 VT Temp" to "BB P1 VR Temp" - Load Exit Air Temp sensor only with Redundant PSU - Rearrange HDD X Status sensors for each HSBP - Correct FSC version to 03 - Correct FSC record type to 02 - Follow Silver_FSC_Config_Sheet_Rev0.41 - Modify Domain mask to 01 for fans-off record S1200SP_002: - Remove probe processor 1 and force set the tag in master.cfg - Remove clear sticky tag for power supply related in master.cfg - Modify readable/settable mast for System Airflow - Modify BB P1 VT Temp for threshold and remove as/de event mask - Modify BB Mem VR Temp for threshold and remove as/de event mask - Modify System Fan 1 sensor number from 0x30 to 0x34 - Modify Processor 1 Fan sensor number from 0x36 to 0x30 - Add CPU Missing sensor(0x82) SDR - Modify readable/settable mast for Agg Therm Mgn 1/2/3/4/5/6 - Modify HSBP Health sensor name to 1 based - Remove MTT CPU2 SDR S1200SP_001: - First release ============================================================================= REFERENCE MATERIAL ============================================================================= Common IBMC Firmware EAS Common Platform IBMC FW EPS Silver_FSC_Config_Sheet_Rev1.00 datasheet [END OF RELEASE NOTES]